Agrivoltaic farming is the practice of growing crops underneath solar panels. It uses the shaded space left empty under solar panels to grow crop. This is doubling up the land use in this way it could help feed the world’s growing population while providing sustainable energy. According to recent studies, there are shade loving plants which thrive when grown in such environment.

Researchers in South Korea have been growing broccoli underneath photovoltaic panels. The panels are positioned 2-3 meters off the ground and sit at an angle of 30 degree providing shade and offering crop protection from the weather.

A study in this project found that the quality of broccoli was not any lower than that of broccoli grown in traditional way.

An Agrivoltaic farming project in Kenya is using solar panels held several meters off the ground, with gap in between them. The shade from the panels protects vegetables from heat stress and water loss.This has resulted in rural farmers being able to grow a greater range of higher-value crops. The project effectively harvests the power of sun twice, the researchers say.

If solar panels can be added to greenhouses, the results could be especially transformative. Greenhouse-based farming reportedly produces 10 times more food than growing in an open field, but it can require 10 times as much power.

This project was alloted to Akash, his internship is about to finish in few days, so I have to continue this project further. This project is on Agrivoltaic farming and under this project we are firstly focusing on plant architecture section. There are some plants such as marigold, okra, chilli, tomato, brinjal, cucumber, chrysanthemum, which are planted in an open field to measure the plant parameters till their full growth. Weekly measurements of plant parameters and daily observation of plants were in process. This measurements were taken to develop a computerized tree generation on HELIOS Software for further comparative study.

  • Akash explained me about the whole project
  • We went on field to measure plant parameters.

If you are keen to know how this project started from beginning, below I have provided blog link to Akash’s project

https://vadic.vigyanashram.blog/2024/09/28/agrivoltaics-plant-architecture/

  1. Weekly measurements of plant parameters were taken
  2. Weeding in field
  3. Cleared certain doubts regarding parameters to be measured with Akash.

25/10/24

Drenching was done by 90 gm of 0:52:34 in 15 litres of water

Daily observation of plants which includes observation of leaves, flowers, fruits and providing dosing and sprays accordingly. Check soil moisture and provide irrigation to plants.

  1. Weekly measurements of plant parameters were taken.
  2. Filling data in excel sheet, uploading plant photos on drive.
  3. Weeding in poly bags.

Link to photos of plants captured weekly

https://drive.google.com/drive/folders/1BZol6tZFD8qTD1NHvt8fqiKBOnglBTkx

Link to excel sheet

https://docs.google.com/spreadsheets/d/1EQEAPsPe81MVzUb04ZAV5aH3CuzGJ6X4/edit?usp=drivesdk&ouid=116983018007863026538&rtpof=true&sd=true

Weekly measurements of plant parameters were recorded.

Took photographs of plants to upload.

Filling measurement data in excel sheet

Link to excel sheet

https://docs.google.com/spreadsheets/d/1F1Q5y166yORJyOUefnkVfv_AyCN0a6vC/edit?usp=drivesdk&ouid=116983018007863026538&rtpof=true&sd=

Link to photos of plants

https://drive.google.com/drive/folders/1Fqx0dBNdwtQIh-eYsZ7WsKQ6kJL9kqKR

Leaf miner on Cucumber leaves were seen

Add 0.5 ml of Gracia insecticide in 500 ml of water. Spraying was done on cucumber leaves at evening 5:00 pm

Yellowing of leaves were observed in cucumber, brinjal and tomato so we did drenching of 13:40:13 (NPK water soluble fertilizer) which is useful in healthy vegetative growth, flowering and fruiting stage of plants.

We took 20 gm of 13:40:13 fertilizer for 10 litres of water ,there are total 90 plants so that per plant will get 100 ml of fertilizer drenching.

Weekly measurements of plant parameters were recorded.

Chilli, tomato, okra, brinjal are at fruiting stage.

Flowering buds are seen on rose and chrysanthemum.

Spraying of insecticide

PALLET ( Propargite 57% EC ) is a insecticide used to control all type of mites and thrips in many crops like brinjal, okra, chillies and other crops. Thrips and mites were observed on leaves of chrysanthemum, chilli, okra and brinjal. To control insects we sprayed insecticide on leaves of plants.

Quantity:

Water – 2 litres

Insecticide- 4 ml

Identification of insects

Fig. Black thrips on chilli

Fig. Yellow mites on Okra

Fig. Black thrips and white flies on Okra

Uploaded data on excel sheet.

Link to excel sheet

https://docs.google.com/spreadsheets/d/1F1Q5y166yORJyOUefnkVfv_AyCN0a6vC/edit?usp=drivesdk&ouid=116983018007863026538&rtpof=true&sd=true

Link to photos

https://drive.google.com/drive/folders/1I6HItvDdpFw11RRC4gRtZHligrFJXuLA

Compost fertilizer was provided to all plants. In quantity of 200 gm per plant. Compost fertilizer helps to grow plant healthier and stronger. It improves organic matter content and then provides essential macro and micro nutrients for plant growth.

Weekly measurements of plant parameters were recorded.

Filling of plant data measurement on excel sheet and uploading photos of plants on google drive.

Link to excel sheet

https://docs.google.com/spreadsheets/d/1F1Q5y166yORJyOUefnkVfv_AyCN0a6vC/edit?usp=drivesdk&ouid=116983018007863026538&rtpof=true&sd=true

23/11/24

Insects, flies were seen on leaves in increasing numbers so we hanged yellow sticky flytraps. Yellow sticky traps with pheromone in glue are used to seize the male pests, which are lured by pheromone, thus to reduce the mating between male and female pests, and reduce their next generation and quantity. Yellow pests attracts to yellow colour and fly towards it, gets stick and die.

Did insecticide spraying on leaves of chrysanthemum, chilli and okra.

Name: Orgomite

Quantity: 2 ml in 1 litre water

Above pdf includes detail information about LI-COR portable photosynthesis machine.

On 5th Jan, Ravi sir and Nimish sir from APV sunseed visited to our VA campus to provide training on operating the LI-COR 6800 Photosynthesis machine. Following 3 days of hands on practice, we started recording photosynthesis rate measurements through ACI, AQI and VPD curves. For each species of plant a total 30 curves were to be collected. Recently, we have completed strawberry and cucumber and have started for turmeric.

On 14 January, new sets of plants were planted, with five replicates each of:

  • Okra
  • Chrysanthemum
  • Chilli
  • Brinjal
  • Tomato

These plants will be used for recording plant architecture data and LI-COR photosynthesis machine data, enabling to study their growth and photosynthetic characteristics.

It was decided to measure plant architecture data once in 15 days and take photos of plants weekly

Recorded photosynthesis readings of various parameters, including:

– ACI (photosynthesis vs intracellular concentration of CO2)

– AQI (photosynthesis vs light response)

– VPD (Vapor Pressure Deficit) or stomatal conductance-

Completed readings for the following plants:

1. Turmeric

2. Fenugreek

3. Rose

Took plant architecture measurements for the plants namely chrysanthemum, brinjal, chilli, tomato.

Almost all plants, except brinjal, which was replanted in Phase 2, withered due to heat stroke. So it is decided to replant those left plants for plant architecture measurements in Polyhouse

Maker’s Mela Event (21/2/25-22/2/25)

Participated in Maker’s Mela held at Somaiya University, Vidyavihar, Mumbai

Objective: Provide a platform for innovative projects and cutting-edge technologies

– Exhibited products from Vigyan Ashram:

– H2S water testing kit

– Agri waste decomposer

– AKXY home composter

– Polyhouse data Loggers

showcased projects converted into business:

– Production of Black soldier fly and managing wet waste by black soldier fly larva

-displayed automation projects from Vigyan Ashram’s DIY lab:

1. Line follower robot

2. Motion detector robot

3. Calculator

4. Soil moisture sensor

5. Solar lamp

6. Walking robot

Fig. Team Vigyan Ashram at Maker’s Mela

Fig. Engaged with students and stall visitors

Two days experience at exhibition was most valuable in developing my soft skills. I exchanged ideas with various visitors visiting at stall.

25/2/25—9/3/25

Sayali joined our Agrivoltaics team as an intern to assist with collecting LI-COR photosynthesis readings from plants. Before handling her with the machine, I provided thorough training, covering the fundamentals of machine operation and beyond. After two days of hands-on practice, I introduced her to the scientific principles of the machine. I intentionally delayed sharing this information to avoid overwhelming her initially.

5/3/25

Nimish sir visited Vigyan Ashram, he shared some insights about how the Li-COR data we collect from plants through photosynthesis machine is processed further. Data is processed in 2 stages by Ravi sir first and then final stage is done by Nimish sir. So he explained his part of work which he does from website of GIZ

6/3/25 – 26/3/25

Plantation of plants for plant architecture measurements was done.

Further I assisted to Sayali for taking plant photosynthesis data with her alternatively

27/3/25

Nimish Sir visited campus for discussion regarding microclimate in polyhouse. Meeting and Discussion on Polyhouse MicroclimateDiscussed about Polyhouse microclimate with Nimish sir and Dixit .

The primary focus of the discussion was on the experimental design and methodology for investigating the effects of foggers and cellulose pad treatments on the Polyhouse environment.

Fogger Testing:

The proposed experiment involves testing three different foggers (designated A, B, and C) to evaluate their performance and efficacy in controlling the Polyhouse microclimate. The foggers will be evaluated using both untreated and treated water solutions to assess the impact of algae-induced effects on the system.

Cellulose Pad Experiment:

The experiment will also investigate the effects of using different water solutions (untreated and treated) on the cellulose pad. This will help to determine the optimal treatment conditions for minimizing algae growth and maximizing the pad’s performance.

Heat Calculations:

Calculations will be performed to determine the amount of heat trapped within the fully covered Polyhouse. This information will be used to estimate the required water evaporation rate to maintain a stable and optimal microclimate.

Data Logger Placement:

The positions of data loggers within the Polyhouse will be determined to ensure accurate and representative measurements of the microclimate conditions.

Future Work:

The discussion outlined the work to be carried out further, including the experimental design, data collection, and analysis. The meeting concluded with a clear plan for the next steps in the project.

Date: 10/4/25

Preparing experimental setup for Evaluation of Algal Growth on Cellulose Cooling Pads Using Treated and Untreated Water

Objective: To investigate the effect of treated versus untreated (algae-rich) water on algal growth on cellulose cooling pads, and assess the effectiveness of oxalic acid and lime treatment in preventing algal biofilm formation, which can reduce pad efficiency due to clogging

Materials Required:

Cellulose cooling pads (2 units, each 0.12 m², reused from scrap)

Submersible pumps (2 units)

Lateral pipes (from scrap)

Water collector trays (from BSF)

Buckets (as water reservoirs)

T-angles and L-angles (for structural support)

Oxalic acid

lime (calcium hydroxide)

Experimental Setup:

Two identical cooling pad systems were assembled using above materials:

A lateral pipe was horizontally installed on a supporting pad, with holes drilled along its length at gaps of 5-5 cm to ensure even water distribution. One end of this lateral was connected to L angle pvc fitting, while the other end was joined to a submersible pump submerged in bucket serving as a water reservoir.

Water Types:

Unit A (Control): Supplied with untreated water rich in algae (“green water”).

Unit B (Treated): Supplied with the same algae-rich water, pre-treated using oxalic acid and lime.

Procedure:

Prepare two systems with identical design and operational parameters.

In Unit A, fill the water tank with untreated algae-rich water.

In Unit B, pre-treat the algae water using:

Oxalic acid is sufficient to disrupt algal cell walls.

Lime to raise water pH, creating a unfavourable environment for algal survival and reproduction.

Circulate the respective water types continuously over the cellulose pads using the submersible pumps.

Observation:

Visual algal growth on pad surfaces.

Continue monitoring over a period of one month, noting changes.

Conclusion: If a pad over which treated water is supplied doesn’t form alga then this treated water will be used to supply over pads in polyhouse.

Date: 14/4/25

Below I have share the documentation of 1 st discussion on heat measurement. This is basically theoritical ideas of how heat is transferred in polyhouse and get trapped increasing the temperature inside.

https://docs.google.com/document/d/1DvMgFhyFP-KS0qgh2gTQa8xHVdIjATL6/edit?usp=sharing&ouid=116983018007863026538&rtpof=true&sd=true

16/4/25

2th discussion on heat measurement

https://docs.google.com/document/d/193rM42EQdbcVknkQ8DvnbT2ZGggW38E1/edit?usp=sharing&ouid=116983018007863026538&rtpof=true&sd=true

19/4/25

3 rd discussion on heat measurement. This calculation is done by recording actual temperature over a period of time

https://docs.google.com/document/d/1L_6Rq_m09UVAdQYzcQN-8GsNlrZOqqLy/edit?usp=sharing&ouid=116983018007863026538&rtpof=true&sd=true

22/4/25

On April 22, 2025, Nimish Sir visited the VA campus to review our polyhouse heat measurement data and calculations. Following the presentation, we decided a timeline for installing foggers and data loggers to initiate controlled experiments.

Installation Timeline:

  • By April 25: Complete the installation of fogging systems within the polyhouse.
  • April 26–27: Hardware connections and arduino code uploading over esp32 boards; and installation of data loggers at different positions in polyhouse.
  • April 28–29: Commence data recording following the experimental procedure:
    1. Allow the polyhouse to reach its peak maximum temperature.
    2. Activate the fogging system to reduce the internal temperature to match or fall below the external ambient temperature.
    3. After deactivating the foggers, observe and record the rate at which the internal temperature rises.

This procedure aims to analyze the polyhouse’s heat gain dynamics, particularly during periods of intense solar radiation, to better understand and manage its internal climate as we have to lower down internal temperature.

  • By 1-3 of May

To determine the cooling efficiency of the fogging system in the polyhouse, a systematic procedure involving water application measurement and temperature monitoring is proposed:

1. Measurement of Water

  • Preparation: Place absorbent materials, such as blankets or sacks, uniformly over the polyhouse floor to capture water droplets emitted by the foggers.
  • Fogging Operation: Activate the fogging system for a duration of 10–15 minutes.
  • Post-Fogging Measurement: Immediately after fogging, carefully collect and weigh the wetted absorbent materials without allowing any water to drip off. This weight indicates the amount of water deposited directly onto surfaces.
  • Water Usage Assessment: Record the water level in the fogger supply tank before and after the fogging operation to determine the total volume of water utilized.
  • Evaporated Water Calculation: Subtract the volume of water collected on the absorbent materials from the total water used to estimate the amount of water that evaporated into the air.

2. Determination of Cooling Rate:

  • Temperature Monitoring: Measure the internal air temperature of the polyhouse immediately before activating the foggers and continuously monitor it during and after the fogging process.
  • Cooling Rate Calculation: Calculate the rate of temperature decrease (ΔT) over the time interval (Δt) during which the foggers are active using the formula: ΔT/Δt

This methodology provides the fogging system’s performance in reducing polyhouse temperatures.

24/4/25-26/4/25

On 24/4/25 recieved 10 data loggers, first I did hardware connections then uploaded arduino code over ESP32 board.

Fig. Hardware connections of Dataloggers

Fig. Compiling Arduino code on ESP32 boards.

27/4/25

Three poles were installed for fixing dataloggers, with one pole placed in each of the three central sections of the poly-house. This installation was done with the help of Aayush and Chaidwik.

28/4/25

Gopal did wirings for dataloggers and fixed dataloggers to poles

29/4/25

Recorded temperature curve data by reducing temperature by foggers till the outer temperature or below that and then analyse how temperature increases over a peak time when sun is on zenith. According to timeline we were to finish this experiment about 27-28 th, but due to delay in datalogger installation I recorded readings today, when I started foggers the temperature was 65 degree C and further temperature reduced till 45 degree celsius with humidity 80% . This delta of 20 degrees got within 12 mins by foggers, the temperature did’nt fell below 45 degree C even if outer temperature was 38 degree C with humidity of 17 %. Temperature didn’t reduced due to steady state of polyhouse, heat accumulated in polyhouse and there was limited internal air circulation which made it difficult to reduce temperature.

Below is the link to google sheet

https://docs.google.com/spreadsheets/d/1FpXWr2WNtQqsqzF_SLzNfRPrkw39sEEY/edit?usp=sharing&ouid=116983018007863026538&rtpof=true&sd=true

So, it was decided to place a fan for internal air circulation and repeat the same readings.

7/5/25

I have attached link to discussion note and calculations for determining CFM of fans to be installed.

https://docs.google.com/document/d/1Hv3RJ3EMfanzhD_cqSiZSKfnBtXBf4nIpoV7QxySjxM/edit?usp=sharing

This note shows that at 1000W/m^2 solar irradiance the heat traps in polyhouse is 12.8 kj/s to remove this heat the air flow should be 8475 approx. 8000 CFM.
 

10/5/25 – 12/5/25

Objective:

To calculate the required CFM of fans for maintaining optimal temperature conditions (up to 35°C) in a polyhouse by quantifying heat gain (practically by performing experiment) and determining necessary airflow rates in CFM.

Method:

The experiment involved cooling the polyhouse using foggers, fans, and adjusting side vents. Temperature rise was recorded from a lower temperature to 35°C, and heat gain was calculated to determine the required airflow rate (CFM) so that the temperature inside polyhouse will remain to 35 degree celsius only even at higher temperatures outside.

Procedure

  1. Cooling Phase : Polyhouse temperature was reduced using foggers, fans, and side vents.
  2. After getting temperature reduce point the foggers and fan were deactivated, vents were closed and to avoid evaporation of water from soil ; surface was covered with HDPE sheet as HDPE sheet is a bad conductor of heat. The reason behind covering the surface by HDPE sheet is evaporation could consume heat (latent heat of vapourization) and slow down the temperature rise. Covering the surfaces isolates the heating process from this effect and gives more accurate temperature rise data.
  3. Temperature rise measurement : Temperature increase was recorded until reaching 35°C.
  4. Heat gain calculation : Total heat gain was calculated based on temperature rise data.
  5. CFM determination : Required CFM was determined based on calculated heat gain.

Following is the link to data and calculation based on it.

https://docs.google.com/spreadsheets/d/1mmOM4D2imq9SuQ_DSm1qS9–4F0_utlO/edit?usp=sharing&ouid=116983018007863026538&rtpof=true&sd=true

Heat Gain Calculation

The experiment yielded a heat gain of 2.99 kJ/s that to on a sunny day, which was lower than the calculated value of 12.8 kJ/s under 1000 W/m² solar irradiance.

To remove this 2.99 kj/s of heat the air flow required and exhaust fan flow rate required in CFM.

We will use the same heat transfer formula Q=m˙⋅cp⋅ΔT to find out mass of air

Q = heat trapped in kj/s = 2.99 Kj/s

Cp = specific heat capacity of air = 1.005 Kj/s

ΔT = (outer air temperature – internal air temp) = (30 – 27.5) = 2.5

m = mass of air

2.99 = m x 1.005 x 2.5 

m= 2.99 kg/ 2.51 kg per m^3

m= 1.19 m^3/s

Air flow = 1.19 m^3 / 5.5 m^2 = 0.21 m/s 

m = 1.19 m^3/s which is equal to 2521.46 CFM (Practical value)

Based on the heat gain values, the corresponding CFM requirements were:

– Approx. 8000 CFM for 12.8 kJ/s heat gain (calculative value)

– Approx. 2000 CFM for 2.99 kJ/s heat gain (practical value)

Fan Selection

Considering these values, it was decided to install fans with a CFM rating of 4000, which is approximately half of 8000 CFM (calculative value) and double of 2000 CFM (practical value).

As we know that it is decided to install 8 fans of 500 CFM each in staggered way. So we searched fans of 500 CFM but we didn’t got the stated 500 CFM on fan as specification. The specifications were flow rate and rpm, so we got one fan with flow rate 1000 m^3/hr. Calculated CFM by converting m^3/hr to CFM. Here how I did:

1 m^3/hr = 0.5886 CFM

So,

1000 x 0.5886 = 588.6 CFM

This was calculative data, so to confirm the actual CFM of fan we decided to test the CFM of fan practically and if the CFM matches than install the fans.

  1. Fabricate frustum from HDPE sheet in such a way that the diameter of one end should be equal to diameter (76.2 cm) of exhaust fan outlet and diameter of another end should be equal to diameter (7.5 cm) of anemometer fan opening.
  2. Maintain a straight length between 2 ends equal to 3 times of the exhaust fan’s outlet diameter to create laminar airflow at the measuring end.
  3. Securely attach the large end of the frustum to the exhaust fan outlet, ensuring an airtight seal.
  4. For checking CFM first set the cross-sectional area of smaller end, then set CFM screen on anemometer.
  5. Position the anemometer probe at the small end so it measures airflow without leakage around the edges.
  6. Run the exhaust fan and stabilize airflow for atleast 5-8 mins. to ensure steady readings.
  7. Record air flow.

Result :

726 CFM of airflow was recorded practically.

Had a call with Nimish sir in presence of Abhijeet and Ranajeet sir regarding microclimate readings

MoM of call :

  1. If humidity is too high, suspend micro-climate measurements till we get dry spells.
  2. Prior to that, to be ready with everything, so that fan- pad measurements canalso be done in same dry weather.
  3. Arrange sealingof side rollable vents.
  4. o get pad window opened and velcrowed and use the same for venting and fogging if internal temperature is too high.
  5. To work on experiment for choking of foggers.
  6. To communicate final method of measurement for fogger efficiency and keep it in written.